۱ | 3BSE069966R1 | TU854
| The TU854 MTU can have up to 8 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. Input signals are connected via individual shunt sticks, TY801. The shunt stick is used to choose between voltage and current input. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel. The MTU distributes the two ModuleBuses, one to each I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Four mechanical keys, two for each I/O module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Up to 8 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding. (3BSE069966R1)
| تماس بگیرید |
| | | redundant | 50-v | 16 | 25-pin-d-sub | horizontal |
۲ | 3BSE069964R1 | TU852
| The TU852 is a 16 channel module termination unit (MTU) for redundant S800 I/O modules and for mounting on a horizontal DIN rail. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The TU842 MTU can have up to 16 I/O channels and process voltage connections. Each channel has two uncommitted I/O connections. Normally S1-16 (signals) on X1A and U1-16 (power out) on X1B. Each DB25 include terminals for ZP, UP and EM.
The MTU distributes the two ModuleBuses to each I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
Features and benefits
Complete installation of I/O modules using 3-wire connections and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE069964R1)
| تماس بگیرید |
| | | redundant | 50-v | 16 | 25-pin-d-sub | horizontal |
۳ | 3BSE069209R1 | TU818
| The TU818 is a 32 channel 50 V compact module termination unit (MTU) for the S800 I/O. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Compact installation of I/O modules using one-wire or two-wire (depends on I/O module type) connections.
Up to 32 channels of field signals and process power connections.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE069209R1)
| تماس بگیرید |
| | | compact | 50-v | 32 | terminal-block | both-directions |
۴ | 3BSE068891R1 | TU819
| The TU819 is a 50 V compact module termination unit (MTU) for the S800 I/O system with 32 signal connections. The MTU is a passive unit used for connection of the field wiring. It also contains a part of the ModuleBus.
The TU819 MTU can have up to 32 I/O signals. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Compact installation of I/O modules using D-sub 25 connector.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting (3BSE068891R1)
| تماس بگیرید |
| | | compact | 50-v | 32 | 25-pin-d-sub | both-directions |
۵ | 3BSE068782R1 | TU851
| The TU851 MTU can have up to 16 I/O channels. The maximum rated voltage is 250 V and maximum rated current is 3 A per channel. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Up to 16 isolated channels of field signals.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE068782R1)
| تماس بگیرید |
| | | extended | 250-v | 16 | terminal-block | both-directions |
۶ | 3BSE050930R1 | TU850
| The TU850 MTU can have up to 16 I/O channels. The maximum rated voltage is 50 V and maximum rated current is 15mA per I/O channel (digital input) or 25mA per two I/O channels (analog input).
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail. Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete 2-wire connections for up to 16 channels.
Each channel has one current limited sensor/transmitter power outlet terminal and one signal terminal.
Current limitation in sensor/transmitter supply is implemented with disconnectable PTC fuse.
Process voltage can be connected to 2 individually isolated groups, if the I/O module supports it.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE050930R1)
| تماس بگیرید |
| | | extended | 50-v | 16 | terminal-block | both-directions |
۷ | 3BSE046966R1 | TU839
| The TU839 MTU can have up to 8 I/O channels and two groups of connections for sensor power distribution. Each channel has two I/O connections. The process voltage can be connected to two individually isolated groups for sensor power distribution. Each group has a 200 mA fuse. The maximum rated voltage is 250 V and maximum rated current is 1 A per channel. It is recommended that the fuse rating be chosen to meet the applications needs.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
8 individually isolated I/O channels.
Two individually isolated, fused groups for sensor power distribution.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE046966R1)
| تماس بگیرید |
| | | extended | 250-v | 8 | terminal-block | both-directions |
۸ | 3BSE040364R1 | TU834
| The TU834 MTU can have up to 8 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. Input signals are connected via individual shunt sticks, TY801. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel. The MTU distributes the ModuleBus to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Features and benefits
Complete installation of I/O modules using 2-wire connections and field power distribution.
Up to 8 channels of field signals and process power connections.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting.
Include 8 individual shunt sticks. (3BSE040364R1)
| تماس بگیرید |
| | | extended | 50-v | 8 | terminal-block | both-directions |
۹ | 3BSE038726R1 | TU833
| The TU833 MTU can have up to 16 I/O channels and two process voltage connections. Each channel has two I/O connections and one ZP connection. The process voltage can be connected to two individually isolated groups. Each group has a 6.3 A fuse. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel. It is recommended that the fuse rating be chosen to meet the applications needs, see S800 I/O Getting Started chapter Power and Cooling.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Features and benefits
Complete installation of I/O modules using 3-wire connections, fuses and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting.
Spring-case terminal. (3BSE038726R1)
| تماس بگیرید |
| | | extended | 50-v | 16 | crimp-snap-in-connector | both-directions |
۱۰ | 3BSE036714R1 | TU813
| The TU813 is a 8 channel 250 V compact module termination unit (MTU) for the S800 I/O. The TU813 has three rows of crimp snap-in connectors for field signals and process power connections.
The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The maximum rated voltage is 250 V and maximum rated current is 3 A per channel. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Compact installation of I/O modules.
Up to 8 isolated channels of field signal connections with crimped snap-in connectors.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE036714R1)
| تماس بگیرید |
| | | compact | 250-v | 8 | crimp-snap-in-connector | both-directions |
۱۱ | 3BSE021447R1 | TU845
| The TU845 MTU can have up to 8 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. Input signals are connected via individual shunt sticks, TY801. The shunt stick is used to choose between voltage and current input. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel.
The MTU distributes the two ModuleBuses, one to each I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU. It has a mechanical latch that locks the MTU to the DIN rail.
Four mechanical keys, two for each I/O module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete installation of I/O modules using 2-wire connections and field power distribution.
Up to 8 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/Omodule.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE021447R1)
| تماس بگیرید |
| | | redundant | 50-v | 8 | terminal-block | vertical |
۱۲ | 3BSE021445R1 | TU844
| The TU844 MTU can have up to 8 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. Input signals are connected via individual shunt sticks, TY801. The shunt stick is used to choose between voltage and current input. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel.
The MTU distributes the two ModuleBuses, one to each I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Four mechanical keys, two for each I/O module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete installation of I/O modules using 2-wire connections and field power distribution.
Up to 8 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE021445R1)
| تماس بگیرید |
| | | redundant | 50-v | 8 | terminal-block | horizontal |
۱۳ | 3BSE021443R1 | TU843
| The TU843 MTU can have up to 16 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. The maximum rated voltage is 50 V and maximum rated current is 3 A per channel.
The MTU distributes the two ModuleBuses, one to each the I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Four mechanical keys, two for each module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete installation of I/O modules using 3-wire connections and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE021443R1)
| تماس بگیرید | | | | redundant | 50-v | 16 | terminal-block | vertical |
۱۴ | 3BSE020850R1 | TU842
| The TU842 MTU can have up to 16 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. The maximum rated voltage is 50 V and maximum rated current is 3 A per channel.
The MTU distributes the two ModuleBuses to each I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Four mechanical keys, two for each I/O module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete installation of I/O modules using 3-wire connections and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE020850R1)
| تماس بگیرید |
| | | redundant | 50-v | 16 | terminal-block | horizontal |
۱۵ | 3BSE013238R1 | TU837V1
| The TU837V1 MTU can have up to 8 I/O channels. The maximum rated voltage is 250 V and maximum rated current is 3 A per channel. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail. The latch can be released with a screwdriver. Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Up to 8 individually isolated channels of field signals and process power connections.
Each channel has two terminals and one is fused.
Allows a mix of isolated and grouped channels.
Process voltage return can be connected to two individually isolated groups.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013238R1)
| تماس بگیرید |
| | | extended | 250-v | 8 | terminal-block | both-directions |
۱۶ | 3BSE013237R1 | TU836V1
| The TU836V1 MTU can have up to 8 I/O channels. The maximum rated voltage is 250 V and maximum rated current is 3 A per channel. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Two groups with 4 channels of field signals and process power connections.
Each channel has one fused load power terminal and one signal return connection.
Process voltage can be connected to 2 individually isolated groups.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013237R1)
| تماس بگیرید |
| | | extended | 250-v | 8 | terminal-block | both-directions |
۱۷ | 3BSE013236R1 | TU835V1
| The TU835V1 MTU can have up to 8 I/O channels. The maximum rated voltage is 50V and maximum rated current is 2 A per channel. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail. The latch can be released with a screwdriver.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Up to 8 channels of field signals and process power connections.
Each channel has one fused transducer power terminal and one signal connection.
Process voltage can be connected to 2 individually isolated groups.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013236R1)
| تماس بگیرید |
| | | extended | 50-v | 8 | terminal-block | both-directions |
۱۸ | 3BSE013235R1 | TU831V1
| The TU831V1 MTU can have up to 8 I/O channels. The maximum rated voltage is 250 V and maximum rated current is 3 A per channel.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU. The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Features and benefits
Greater connection area for larger wires.
Up to 8 isolated channels of field signals.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013235R1)
| تماس بگیرید |
| | | extended | 250-v | 8 | terminal-block | both-directions |
۱۹ | 3BSE013234R1 | TU830V1
| The TU830V1 MTU can have up to 16 I/O channels and two process voltage connections. Each channel has two I/O connections and one ZP connection. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The process voltage can be connected to two individually isolated groups. Each group has a 6.3 A fuse. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel. The MTU distributes the ModuleBus to the I/O module end to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Features and benefits
Complete installation of I/O modules using 3-wire connections, fuses and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013234R1)
| تماس بگیرید |
| | | extended | 50-v | 16 | terminal-block | both-directions |
۲۰ | 3BSE013233R1 | TU814V1
| The TU814V1 MTU can have up to 16 I/O channels and two process voltage connections. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel.
The TU814V1 has three rows of crimp snap-in connectors for field signals and process power connections. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
16 channels for 24 V d.c. inputs with current sourcing
2 Isolated groups of 8 with voltage supervision
Input status indicators (3BSE013233R1)
| تماس بگیرید |
| | | compact | 50-v | 16 | crimp-snap-in-connector | both-directions |
۲۱ | 3BSE013232R1 | TU812V1
| The TU812V1 is a 50 V compact module termination unit (MTU) for the S800 I/O system with 16 signal connections. The MTU is a passive unit used for connection of the field wiring. It also contains a part of the ModuleBus.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Compact installation of I/O modules using D-sub connector.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013232R1)
| تماس بگیرید |
| | | compact | 50-v | 16 | 25-pin-d-sub | both-directions |
۲۲ | 3BSE013231R1 | TU811V1
| The TU811V1 is a 8 channel 250 V compact module termination unit (MTU) for the S800 I/O. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Compact installation of I/O modules.
Up to 8 isolated channels of field signals.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013231R1)
| تماس بگیرید |
| | | compact | 250-v | 8 | terminal-block | both-directions |
۲۳ | 3BSE013230R1 | TU810V1
| The TU810/TU810V1 is a 16 channel 50 V compact module termination unit (MTU) for the S800 I/O. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Compact installation of I/O modules using one-wire connections.
Up to 16 channels of field signals and process power connections.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013230R1)
| تماس بگیرید |
| | | compact | 50-v | 16 | terminal-block | both-directions |
۲۴ | 3BSE008572R1 | TU838
| The TU838 MTU can have up to 16 I/O channels. The maximum rated voltage is 50 V and maximum rated current is 3 A per channel.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Two mechanical keys are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete installation of I/O modules using 3-wire connections, fuses and field power distribution.
Up to 16 channels of field signals and 8 process power connections.
Two channels share one fused transducer power terminal.
Process voltage can be connected to 2 individually isolated groups, if the I/O module supports it.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE008572R1)
| تماس بگیرید |
| | | extended | 50-v | 16 | terminal-block | both-directions |
۲۵ | 3BSC840157R1 | TU891
| The TU891 MTU has gray terminals for field signals and process voltage connections. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel, but these are primarily constrained to specific values by the design of the I/O modules for their certified application. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I.S. I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. The keys used on the TU891 are of the opposite gender to those on any other type of MTU and will mate only with IS I/O modules.
Features and benefits
Intrinsic safety applications – use with AI890, AI893, AI895, AO890, AO895, DI890 and DO890
Compact installations of I/O modules
Field signals and process power connections
Connections to ModuleBus and I/O modules
Mechanical keying prevents insertion of the wrong module
Latching device to DIN rail
DIN rail mounting (3BSC840157R1)
| تماس بگیرید |
| | | compact | 24-v | 8 | terminal-block | horizontal |
۲۶ | 3BSC690075R1 | TU890
| The TU891 is a compact MTU for the S800 I/O. The MTU is a passive unit used for connection of the field wiring and power supply to the I/O modules. It also contains a part of the ModuleBus. The TU891 MTU has gray terminals for field signals and process voltage connections. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel, but these are primarily constrained to specific values by the design of the I/O modules for their certified application.
The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Features and benefits
Intrinsic safety applications – use with AI890, AI893, AI895, AO890, AO895, DI890 and DO890
Compact installations of I/O modules
Field signals and process power connections
Connections to ModuleBus and I/O modules
Mechanical keying prevents insertion of the wrong module
Latching device to DIN rail
DIN rail mounting (3BSC690075R1)
| تماس بگیرید |
| | | compact | 24-v | 8 | terminal-block | horizontal |