The TU830V1 MTU can have up to 16 I/O channels and two process voltage connections. Each channel has two I/O connections and one ZP connection. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The process voltage can be connected to two individually isolated groups. Each group has a 6.3 A fuse. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel. The MTU distributes the ModuleBus to the I/O module end to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Features and benefits
Complete installation of I/O modules using 3-wire connections, fuses and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013234R1)
| وزن | 0.28 کیلوگرم |
|---|---|
| ابعاد | 126 × 110 سانتیمتر |
| نوع محصول | Extended |
| Connection | Terminal block |
| تعداد کانال | 16 |
| ولتاژ کاری (V) | 50 V |
| Mounting | Both directions |
| ماژول های مرتبط | AI810, AI815, AI820, AI830, AI830A, AI835, AI835A, AI843, AI845, AO810, AO810V2, AO815, AO820, AO845, AO845A, DI810, DI811, DI814, DI818, DI830, DI831, DI840, DI880, DI885, DO810, DO814, DO815, DO818, DO840, DO880, DP820 and DP840 |
محصولات مرتبط
توضیحات محصولات
The TU830V1 MTU can have up to 16 I/O channels and two process voltage connections. Each channel has two I/O connections and one ZP connection. The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus.
The process voltage can be connected to two individually isolated groups. Each group has a 6.3 A fuse. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel. The MTU distributes the ModuleBus to the I/O module end to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Features and benefits
Complete installation of I/O modules using 3-wire connections, fuses and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to ModuleBus and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE013234R1)
توضیحات تکمیلی
| وزن | 0.28 کیلوگرم |
|---|---|
| ابعاد | 126 × 110 سانتیمتر |
| نوع محصول | Extended |
| Connection | Terminal block |
| تعداد کانال | 16 |
| ولتاژ کاری (V) | 50 V |
| Mounting | Both directions |
| ماژول های مرتبط | AI810, AI815, AI820, AI830, AI830A, AI835, AI835A, AI843, AI845, AO810, AO810V2, AO815, AO820, AO845, AO845A, DI810, DI811, DI814, DI818, DI830, DI831, DI840, DI880, DI885, DO810, DO814, DO815, DO818, DO840, DO880, DP820 and DP840 |