TU843
ناموجود
12 ماه گارانتی
12 ماه گارانتی
10 سال خدمات
پس از فروش
10 سال خدمات
پس از فروش
پرداخت در محل
مشهد و تهران
پرداخت در محل
مشهد و تهران
ضمانت اصالت کالا
ضمانت اصالت کالا
The TU843 MTU can have up to 16 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. The maximum rated voltage is 50 V and maximum rated current is 3 A per channel.
The MTU distributes the two ModuleBuses, one to each the I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Four mechanical keys, two for each module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete installation of I/O modules using 3-wire connections and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE021443R1)
وزن | 0.6 کیلوگرم |
---|---|
ابعاد | 131 × 186.5 سانتیمتر |
نوع محصول | Redundant |
Connection | Terminal block |
تعداد کانال | 16 |
ولتاژ کاری (V) | 50 V |
Mounting | Vertical |
ماژول های مرتبط | AI843, AO845, AO845A, DI840, DI880, DO840, DO880 and DP840 |
محصولات مرتبط
توضیحات محصولات
The TU843 MTU can have up to 16 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. The maximum rated voltage is 50 V and maximum rated current is 3 A per channel.
The MTU distributes the two ModuleBuses, one to each the I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU.
The MTU can be mounted on a standard DIN rail. It has a mechanical latch that locks the MTU to the DIN rail.
Four mechanical keys, two for each module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.
Features and benefits
Complete installation of I/O modules using 3-wire connections and field power distribution.
Up to 16 channels of field signals and process power connections.
Connections to two ModuleBuses and I/O modules.
Mechanical keying prevents insertion of the wrong I/O module.
Latching device to DIN rail for grounding.
DIN rail mounting. (3BSE021443R1)
توضیحات تکمیلی
وزن | 0.6 کیلوگرم |
---|---|
ابعاد | 131 × 186.5 سانتیمتر |
نوع محصول | Redundant |
Connection | Terminal block |
تعداد کانال | 16 |
ولتاژ کاری (V) | 50 V |
Mounting | Vertical |
ماژول های مرتبط | AI843, AO845, AO845A, DI840, DI880, DO840, DO880 and DP840 |
نقد و بررسیها
هنوز بررسیای ثبت نشده است.