TU891
ناموجود
12 ماه گارانتی
12 ماه گارانتی
10 سال خدمات
پس از فروش
10 سال خدمات
پس از فروش
پرداخت در محل
مشهد و تهران
پرداخت در محل
مشهد و تهران
ضمانت اصالت کالا
ضمانت اصالت کالا
The TU891 MTU has gray terminals for field signals and process voltage connections. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel, but these are primarily constrained to specific values by the design of the I/O modules for their certified application. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I.S. I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. The keys used on the TU891 are of the opposite gender to those on any other type of MTU and will mate only with IS I/O modules.
Features and benefits
Intrinsic safety applications – use with AI890, AI893, AI895, AO890, AO895, DI890 and DO890
Compact installations of I/O modules
Field signals and process power connections
Connections to ModuleBus and I/O modules
Mechanical keying prevents insertion of the wrong module
Latching device to DIN rail
DIN rail mounting (3BSC840157R1)
وزن | 0.17 کیلوگرم |
---|---|
ابعاد | 64 × 194 سانتیمتر |
نوع محصول | compact |
Connection | Terminal block |
تعداد کانال | 8 |
ولتاژ کاری (V) | 24 V |
Mounting | Horizontal |
ماژول های مرتبط | AI890, AI893, AI895, AO890, AO895, DI890, DO890 |
محصولات مرتبط
توضیحات محصولات
The TU891 MTU has gray terminals for field signals and process voltage connections. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel, but these are primarily constrained to specific values by the design of the I/O modules for their certified application. The MTU distributes the ModuleBus to the I/O module and to the next MTU. It also generates the correct address to the I/O module by shifting the outgoing position signals to the next MTU.
Two mechanical keys are used to configure the MTU for different types of I.S. I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. The keys used on the TU891 are of the opposite gender to those on any other type of MTU and will mate only with IS I/O modules.
Features and benefits
Intrinsic safety applications – use with AI890, AI893, AI895, AO890, AO895, DI890 and DO890
Compact installations of I/O modules
Field signals and process power connections
Connections to ModuleBus and I/O modules
Mechanical keying prevents insertion of the wrong module
Latching device to DIN rail
DIN rail mounting (3BSC840157R1)
توضیحات تکمیلی
وزن | 0.17 کیلوگرم |
---|---|
ابعاد | 64 × 194 سانتیمتر |
نوع محصول | compact |
Connection | Terminal block |
تعداد کانال | 8 |
ولتاژ کاری (V) | 24 V |
Mounting | Horizontal |
ماژول های مرتبط | AI890, AI893, AI895, AO890, AO895, DI890, DO890 |
نقد و بررسیها
هنوز بررسیای ثبت نشده است.